Polymer Films as Calibration Standards for X-ray Fluorescence Analysis

  • T. G. Dzubay (a1), P. J. Lamothe (a1) and H. Yasuda (a2)

Abstract

A new type of calibration standard has been developed for X-ray fluorescence analysis of thin samples. Each standard consists of a polymer film containing a single calibration element. The film is cast from a homogeneous solution containing known amounts of an organometallic compound and a polymer. Polymers of cellulose acetate-propionate and polystyrene are used because of their low moisture affinity. The films have a low (2-4 mg/cm2) mass per unit area for minimal X-ray attenuation. Standards of V, Co, Hi, and Pb have been successfully made. Typical concentrations of 20 μg/cm2 yield excellent spectra with a low background. The method shows promise for making standards of additional elements.

    • Send article to Kindle

      To send this article to your Kindle, first ensure no-reply@cambridge.org is added to your Approved Personal Document E-mail List under your Personal Document Settings on the Manage Your Content and Devices page of your Amazon account. Then enter the ‘name’ part of your Kindle email address below. Find out more about sending to your Kindle. Find out more about sending to your Kindle.

      Note you can select to send to either the @free.kindle.com or @kindle.com variations. ‘@free.kindle.com’ emails are free but can only be sent to your device when it is connected to wi-fi. ‘@kindle.com’ emails can be delivered even when you are not connected to wi-fi, but note that service fees apply.

      Find out more about the Kindle Personal Document Service.

      Polymer Films as Calibration Standards for X-ray Fluorescence Analysis
      Available formats
      ×

      Send article to Dropbox

      To send this article to your Dropbox account, please select one or more formats and confirm that you agree to abide by our usage policies. If this is the first time you use this feature, you will be asked to authorise Cambridge Core to connect with your <service> account. Find out more about sending content to Dropbox.

      Polymer Films as Calibration Standards for X-ray Fluorescence Analysis
      Available formats
      ×

      Send article to Google Drive

      To send this article to your Google Drive account, please select one or more formats and confirm that you agree to abide by our usage policies. If this is the first time you use this feature, you will be asked to authorise Cambridge Core to connect with your <service> account. Find out more about sending content to Google Drive.

      Polymer Films as Calibration Standards for X-ray Fluorescence Analysis
      Available formats
      ×

Copyright

References

Hide All
1. Pradzynski, A. H. and Rhodes, J. R., “Development of Synthetic Standard Samples for Trace Analysis of Air Particulates Publication 598, p.320336, American Society for Testing and Materials (1976).
2. Camp, D. C., VanLehn, A. L., Rhodes, J. R., and Pradzynski, A. H., “Intercomparison of Trace Element Determinations in Simulated and Real Air Particulate Samples,” X-Ray Spectrom. 4, 123137 (1975).
3. Baum, R. M., Gutknecht, W. F., Willis, R. D., and Walter, R. L., “Preparation of Standard Targets for X-Ray Analysis,” Anal. Chem. 47, 1727-1728 (1975).
4. Stiles, A. R., Dzubay, T. G., Baum, R. M., Walter, R. L., Willis, R. D., Moore, L. J., Garner, E. L., Gramlich, J. W., and Machlan, L. A., “Calibration of an Energy Dispersive X-Ray Fluorescence Spectrometer,” in Gould, R. W., Barrett, C. S., Newkirk, J. B., and Ruud, C. O., Editors, Advances in X-Ray Analysis Vol. 19, p.473 486, Kendall/Hunt (1976).
5. Giauque, R. D., Garrett, R. B., and Goda, L. Y., “Calibration of Energy Dispersive X-Ray Spectrometers for Analysis of Thin Environmental Samples,” in X-Ray Fluorescence Methods for Analysis of Environmental Samples, Chapter 11, Ann Arbor Science (1976).
6. Jaklevic, J. M., Goulding, F. S., Jarett, B. V., and Meng, J. D., “Applications of X-Ray Fluorescence Techniques to Measure Elemental Composition of the Atmosphere,” in Stevens, R. K. and Herget, W. Y., Editors, Analytical Methods Applied to Air Pollution Measurements p.123146, Ann Arbor Science (1974).

Polymer Films as Calibration Standards for X-ray Fluorescence Analysis

  • T. G. Dzubay (a1), P. J. Lamothe (a1) and H. Yasuda (a2)

Metrics

Full text views

Total number of HTML views: 0
Total number of PDF views: 0 *
Loading metrics...

Abstract views

Total abstract views: 0 *
Loading metrics...

* Views captured on Cambridge Core between <date>. This data will be updated every 24 hours.

Usage data cannot currently be displayed