Abstract

Lobov et al., in Leningrad, and workers at this laboratory have been working on the idea of using x rays from radioactive sources for x ray diffraction analysis. The Russians have been using iron-55 produced by the (n, Y) reaction in their work with a small focusing camera which operates in the back reflection region. We have been using iron-55 produced by the (p,n) reaction in conjunction with a small Debye-Scherrer camera. The preliminary work of this laboratory was reported at this conference two years ago. At that time a 13 mCi iron-55 source was used in a two inch diameter Debye-Scherrer camera to obtain x-ray diffraction patterns of LiF. The exposure times were of the order of 120 hours and the reflection from the 200 plane was about 3 degrees wide. Since that time a new and more intense source has been constructed at Oak Ridge National Laboratories. With the new source it was possible to produce LiF diffraction patterns of the same density and resolution as before in a period of less than ten hours.

The above mentioned diffraction patterns were made with the LiF powder placed in a 1.0 mm diameter glass capillary. After reduction of the glass capillary diameter to 0.5 mm and appropriate reduction of the collimator width, we were able to improve the resolution considerably with no accompanying reduction in line density. The LiF patterns obtained in this way required an exposure time of about 20 hours and the width of the reflection from the 200 plane has been reduced to about 1.5 degrees.

Hence we are able to report a reduction in exposure time from 116 hours to 20 hours and an increase in resolution by a factor of two over the data reported here two years ago. Thus the concept of using x rays from an isotope for powder diffraction has changed from a laboratory curiosity into a technique with practical possibilities. Both sources mentioned above were produced by the (p, n) reaction. The 135 mCi source had a specific activity of about 400 Ci/gm. Since iron-55 sources have been made with specific activities of about 1000 Ci/gm, a considerable decrease in exposure time could be accomplished by using such a source. The application to this work of a position sensitive proportional counter as developed by Semmler will also be discussed.

Type
Research Article
Copyright
Copyright © International Centre for Diffraction Data 1970

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

Lobov, S. I., Funin, V. N., and Zuckerman, V. A., Special Construction Bureau of Roentgen Apparatus, Leningrad, USSR.Google Scholar
Semmler, R. A., Illinois Institute of Technology Research Institute, Chicago.Google Scholar
Semmler, R. A., Evaluation of Fe-55 X-Ray Sources for Portable Stress Analysis Equipment, pp. 639-647, Baker, P. S. and Gerrard, M. (Eds.), in Proceedings of Second Symposium on Low-Energy X- and Gamma Sources and Applications Held at the University of Texas, Austin, March 1967, USAEC Report ORNL-11C-10, Oak Ridge National Laboratory, September 1968.Google Scholar
Preuss, L. E., Toothacker, W. S., and Bugenis, C. K., Demonstration of X-Ray Diffraction by LiF Using the Mn X Rays Resulting from Fe-55 Decay, Appl. Phys. Letters, 9:159 (1966).Google Scholar
Toothacker, W. S., Preuss, L. E., and Bugenis, C. K., Powder Sample and Single Crystal X-Ray Diffraction Utilizing the Electron Capture Radiation of Fe-55 and the Beta Stimulated K X-Ray Doublet, pp. 629638, Baker, P. S. and Gerrard, M. (Eds.), in Proceedings of Second Symposium on Low-Energy X- and Gamma Sources and Applications Held in the University of Texas, Austin, March 1967, USAEC Report ORNL-llC-10, Oak Ridge National Laboratory, September 1968.Google Scholar
Preuss, L. E., Toothacker, W. S., and Bugenis, C. K., Single Crystal X-Ray Diffraction Using Photons from Two Radioactive Isotopic Sources, J. AppL Phys., 38: 34043405(1967).Google Scholar
Toothacker, W. S., Preuss, L. E., and Bugenis, C. K., Debye-Scherrer Powder Diffraction Using Fe-55 K X Rays on Lithium Fluoride, Nature, 216: 255256 (1967).Google Scholar
Preuss, L. E., Toothacker, W. S., and Bugenis, C. K., Investigation and Demonstration of Single Crystal and Powder Diffraction by Using Zero Power Beta Excited X Ray and Fe-55 Isotopic Sources, in Advances in X-Ray Analysis, Vol. 11, pp. 326331, Newkirk, J. B., Mallett, G. R., and Pfeiffer, H. G. (Eds), Plenum Press, New York, 1968.Google Scholar
Preuss, L. E. and Toothacker, W. S., “X Rays from Radioactive Isotopic Sources for Diffraction Analysis”, Isotopes and Radiation Technology 7, 5462 (1969).Google Scholar
Lobov, S. I. and Tsukerman, W. A., Use of Radioactive Sources of Characteristic Radiation in X-Ray Structural Analysis, Dokl, Akad. Nauk SSSR (Engl. Transl. ), 10: 12071208 (1966).Google Scholar
Lobov, S. I., Funin, W. H., and Tsukerman, W. A., Application of Fe-55 Sources for X-Ray Diffraction Analysis of Polycrystalline Specimens, Crystallography (Engl. Transl.), 11 : 523-526 (1966) (Russian original, pp. 599603).Google Scholar
Lobov, S. I., Funin, W. H., and Tsukerman, W. A., Methods and Apparatus for Radioactive Roentgen Structure Analysis, Prib. Tekh. Eksp., 1966(6): 172176.Google Scholar
Lobov, S. I., Funin, V. N., and Zuckerman, V. A., “Photographic Recording of X- ray Diffractions from Powder samples using Fe-55 Sources”, Nature 222, 767768 (1969).Google Scholar
Preuss, L. E. and Toothacker, W. S., Nature, in press.Google Scholar
Toothacker, W. S. and Preuss, L. E., Radioisotopes as Zero Power Sources of X Rays for X-Ray Diffraction Analysis, in Nucleonics in Aerospace, pp. 341343, Polishuk, Paul (Ed,), Plenum Press, New York, 1968.Google Scholar
Gruverman, I., New England Nuclear Corp., Boston.Google Scholar
Semmler, R. A., “A Curved Position Sensitive Detector for X Rays”, in Proceedings of Third Symposium on Low Energy X- and Gamma Sources and Applications Held at Boston College, March 1970, in press.Google Scholar
Bugenis, C. K., Preuss, L. E., and Toothacker, W. S., Laboratory Debye-Scherrer Camera Using and Fe-55 Source of Mn X Rays, Rev. Sci. Instrum., 39: 17541755 (1968).Google Scholar
Semmler, R. A., "A Curved Position Sensitive Detector for X Rays", in Proceedings of Third Symposium on Low Energy X- and Gamma Sources and Applications Held at Boston College, March 1970, in press. Google Scholar