Hostname: page-component-7bb8b95d7b-fmk2r Total loading time: 0 Render date: 2024-09-20T14:19:28.921Z Has data issue: false hasContentIssue false

Detection Confirmation and Determination of Trace Amounts of Selenium by X-Ray Methods

Published online by Cambridge University Press:  06 March 2019

Frank L. Chan*
Affiliation:
Aerospace Research Laboratories Wright-Patterson Air Force Base, Dayton, Ohio
Get access

Abstract

Recently, interest in the determination of selenium in trace amounts has been greatly intensified because of the nutritional aspects of this element. It has been reported that selenium in the amount of 13 μg in the form of sodium selenite in 100 g of feed has an effect similar to that of vitamin E. In the field of semiconductors, the detection and determination of trace amounts of selenium in arsenic, antimony, and small single crystals of solid solution of cadmium selenide and sulfide are of considerable importance in semiconductor performance.

In the Aerospace Research Laboratories, 4,5 diamino-6-tbiopyi-imidine has been successfully adopted as a reagent for the spectrophotometric determination of selenium. The reaction of 4,5 diamino-6-thiopyrimidine and tetxavalent selenium produces a yellow color with the formation of elemental selenium. It is possible to determine elemental selenium by collecting it in a thin layer. The selenium deposited in this layer may then be determined by an X-ray fluorescence method. A procedure of this nature has the advantage of eliminating the matrix effects commonly encountered in X-ray fluorescence. Furthermore, the slow generation of selenium affords a convenient means of detection and confirmation of this element by the use of X-ray diffraction procedures. By this technique selenium is first converted to its tetravalent state and is then reacted with 4,5 diamino-6-thiopyrimidine. On standing, the selenium is reduced to a red precipitate of elemental selenium which can be dissolved in carbon disulfide. Finally, the selenium can be converted into its hexagonal structure by annealing at 205-207°C.

Type
Research Article
Copyright
Copyright © International Centre for Diffraction Data 1963

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

1. Felton, E. J., Fankuchen, I., and Steigman, J., “A Possible Solution, to the Matrix Problem in X-Ray Fluorescence Spectroscopy,” Anal Chem. 31: 1771, 1959.Google Scholar
2. Chan, F. L., “Determination of Zinc Sulfide and Cadmium Sulfide in Solid Solutions of Small Single Crystals Used for Semiconductors by X-Ray and Chemical Methods,” Advances in X-Ray Analysis, Vol. 5, University of Denver, Plenum Press, New York, 1962, p. 142.Google Scholar
3. Chan, F. L., “X-Ray Camera Attachment,” U.S. Patent No. 3,079,500.Google Scholar
4. Chan, F. L., “Some Modifications of the X-Ray Instruments and Their Utilization to the Study of Analytical Problems,” Nordca Reporter (in press).Google Scholar
5. Birks, L. S., X-Ray Spectrochemkal Analysis, Interscience Publishers, Inc., New York, 1959.Google Scholar
6. Burbank, R. D., “The Crystal Structure of a-Monoclinic Selenium,” Acta Cryst. 140: 1951.Google Scholar
7. Donnay, J. D. H. and Donnay, G., Crystal Data, American Crystaltographic Association, 1963.Google Scholar
8. Swanson, H. E., Gilfrich, H. T., and Ugrinic, G. M., Natl. Bur, Standards, Circ, 539, V:54, 1955.Google Scholar