Hostname: page-component-7bb8b95d7b-s9k8s Total loading time: 0 Render date: 2024-09-23T03:37:38.293Z Has data issue: false hasContentIssue false

Concepts of Influence Coefficients in XRF Analysis and Calibration

Published online by Cambridge University Press:  06 March 2019

Richard M. Rousseau*
Affiliation:
Geological Survey of Canada, 601 Booth St., Ottawa, Ont., CANADA, K1A 0E8
Get access

Abstract

A new computer program, named CiROU, has been written to determine the chemical composition of homogeneous samples analyzed by X-ray fluorescence spectrometry (XRF). It uses the furdamental algorithm to convert measured intensities into concentrations anc to correct for matrix effects and runs on any IBM-PC/XT/AT, PS/2 or compatible corrputer.

The program is very easy to use mainly because it is a step-by-step guide to the routine process of analyzing specimens by XRF and because a user friendly interface makes up a main menu bar containing six major options, which provide several other options inside a pull-down window system.

The program is applicable to specimens of any composition with the utmost accuracy that can be obtained from the fundamental-parameters method. It’s unique calibration procedure still adds to the accuracy by eliminating the bias between theory and reality.

The program is a complete “off-line” program allowing to perform all the steps of an XRF analysis: calculation of theoretical influence coefficients, calibration, reading of measured intensities, calculation of net intensities and concentrations of unknowns, print-out of analytical reports and data transmission to or from an external computer.

Type
III. XRF Mathematical Models and Quantitation
Copyright
Copyright © International Centre for Diffraction Data 1988

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

1. Rousseau, R.M., Concepts of Influence Coefficients in XRF Analysis and Calibration, (Also published in the present book).Google Scholar
2. Rousseau, R.M., X-Ray Spectrometry, 13, 115, (1984).Google Scholar
3. Rousseau, R.M., X-Ray Spectrometry, 13, 121, (1984).Google Scholar
4. Rousseau, R.M. and Bouchard, M., X-Ray Spectrometry, 15, 207, (1986).Google Scholar
5. Rousseau, R.M., X-Ray Spectrometry, 16, 103, (1987).Google Scholar
6. Datastorm Technologies, Inc. , Box, P.O. 1471, Columbia, MO 65205, A, U.S..Google Scholar
7. Pella, P.A., Feng, L.Y. and Small, J.A., X-Ray Spectrometry, 14, 125, (1985).Google Scholar
8. Heinrich, K.F.J., The Electron Microprobe, p. 296. Wiley, New York (1966).Google Scholar
9. Thinh, T.P. and Leroux, J., X-Ray Spectrometry, 8, 85, (1979).Google Scholar