Calibration of an Energy Dispersive X-Ray Fluorescence Spectrometer

  • A. R. Stiles (a1), T. G. Dzubay (a2), R. M. Baum (a3), R. L. Walter (a4), R. D. Willis (a4), L. J. Moore (a5), E. L. Garner (a5), J. W. Gramlich (a5) and L. A. Machlan (a5)...

Abstract

The purpose of this work was to develop accurate calibration standards which were fully characterized in terms of uniformity and concentration using fundamental measuring methods. Three similar sets of vacuum deposits were commercially made, each set containing the single deposits CuS, KCl, CaF2, Cr, Fe, Cu, RbNO3, SrF2, MoO3 , BaF2, and Pb. Thickness variations in each deposit were measured with PIXEA (proton induced x-ray excitation analysis) measurements taken at 6 to 8 positions along the deposit diameters. Relative elemental concentrations on corresponding deposits from each set were measured using multiple XRF intercomparisons. One set of deposits was destructively analyzed at the National Bureau of Standards with isotope dilution thermal ionization mass spectrometry (IDMS) in order to calibrate the remaining sets of vacuum deposits. The calibrated deposits were compared with standards from two commercial sources. For seven elements heavier than chlorine there was an average deviation of 13.5% between the calibrated deposits and the commercial standards. Disagreements as large as 15% were observed between standards from the two commercial suppliers.

Copyright

References

Hide All
1. Goulding, F. S. and Jaklevic, J., “X-Ray Fluorescence Spectrometer for Airborne Particulate Monitoring,” EPA Report No. EPA-R2-73-182(1973).
2. Dzubay, T. G. and Stevens, R. K., “Ambient Air Analysis with Dichotomous Sampler and X-Ray Fluorescence Spectrometer,” Envir. Sci. and Tech., 9, 663668 (1975).
3. Giaque, R. D., Goulding, F. S., Jaklevic, J. M. and Pehl, R. H., “Trace Element Determinations with Semiconductor Detector X-Ray Spectrometers ,” Anal. Chem.,45, 671681 (1973).
4. Barnes, I. L., “Determination of Lead, Uranium, Thorium and Thallium in Silicate Glass Standard Materials by Isotope Dilution Mass Spectrometry,” Anal. Chem., 45, 880885 (1973).
5. Moore, L. J., Machlan, L. A., “High Accuracy Determination of Calcium in Blood Serum by Isotope Dilution Mass Spectrometry,” Anal. Chem., 44, 2291-2296 (1972).
6. Moore, L. J., Machlan, L. A., Shields, W. R. and Garner, E. L., “Internal Normalization Techniques for High Accuracy Isotope Dilution Analyses — Application to Molybdenum and Nickel in Standard Reference Materials,” Anal. Chem., 46, 1082-1089 (1974).
7. NBS Technical Note #277, “Analytical Mass Spectrometry Section: Instrumentation and Procedures for Isotopic Analysis,” edited by Shields, W. R. (1966). Available from Supt. of Documents, U. S. Gov't Printing Office, Washington, D. C. 20402.
8. Baum, R. M., Gutknecht, W. F., Willis, R. D., and Walter, R. L. , “Preparation of Standard Targets for X-Ray Analysis,” Anal. Chem. 47, 1727-1728 (1975); see also Anal. Chem., 46, 843-85S (1974).
9. Baum, R. M., Gutknecht, W. F., Walter, R. L. and Stiles, A. R., “Standard Solution Deposits using a Capillary Matrix and Lyophilization,” to be presented at Symposium and Workshop on X-Ray Fluorescence Analysis of Environmental Samples, Environmental Sciences Research Laboratory, EPA, Research Triangle Park, N.C., January 26-28, 1976.
10. Camp, D. C., VanLehn, A. L., Rhodes, J. R., and Pradzynski, A. H., “Intercomparison of Trace Element Determinations in Simulated and Real Air Particulate Samples,” X-Ray Spectrometry, 4, 123137 (1975).

Calibration of an Energy Dispersive X-Ray Fluorescence Spectrometer

  • A. R. Stiles (a1), T. G. Dzubay (a2), R. M. Baum (a3), R. L. Walter (a4), R. D. Willis (a4), L. J. Moore (a5), E. L. Garner (a5), J. W. Gramlich (a5) and L. A. Machlan (a5)...

Metrics

Full text views

Total number of HTML views: 0
Total number of PDF views: 0 *
Loading metrics...

Abstract views

Total abstract views: 0 *
Loading metrics...

* Views captured on Cambridge Core between <date>. This data will be updated every 24 hours.

Usage data cannot currently be displayed