Skip to main content Accessibility help
×
Home
  • Print publication year: 2014
  • Online publication date: September 2014

Chapter 24 - Endpoints of goal directed therapy in the OR and in the ICU

from Section 4: - Goal Directed Hemodynamic Optimization

Related content

Powered by UNSILO

References

1. GrocottMP, MythenMG, GanTJ. Perioperative fluid management and clinical outcomes in adults. Anesth Analg 2005;100:1093–106.
2. MythenMG, WebbAR. Perioperative plasma volume expansion reduces the incidence of gut mucosal hypoperfusion during cardiac surgery. Arch Surg 1995;130:423–9.
3. PrienT, BackhausN, PelsterF, et al. Effect of intraoperative fluid administration and colloid osmotic pressure on the formation of intestinal edema during gastrointestinal surgery. J Clin Anesth 1990;2:317–23.
4. AbbasSM, HillAG. Systematic review of the literature for the use of oesophageal Doppler monitor for fluid replacement in major abdominal surgery. Anaesthesia 2008;63:44–51.
5. GanTJ, SoppittA, MaroofM, et al. Goal-directed intraoperative fluid administration reduces length of hospital stay after major surgery. Anesthesiology 2002;97:820–6.
6. MythenMG, WebbAR. Intra-operative gut mucosal hypoperfusion is associated with increased post-operative complications and cost. Intens Care Med 1994;20:99–104.
7. SinclairS, JamesS, SingerM. Intraoperative intravascular volume optimisation and length of hospital stay after repair of proximal femoral fracture: randomised controlled trial. BMJ 1997;315:909–12.
8. VennR, SteeleA, RichardsonP, et al. Randomized controlled trial to investigate influence of the fluid challenge on duration of hospital stay and perioperative morbidity in patients with hip fractures. Br J Anaesth 2002;88:65–71.
9. GiglioMT, MarucciM, TestiniM, BrienzaN. Goal-directed haemodynamic therapy and gastrointestinal complications in major surgery: a meta-analysis of randomized controlled trials. Br J Anaesth 2009;103:637–46.
10. RhodesA, CecconiM, HamiltonM, et al. Goal-directed therapy in high-risk surgical patients: a 15-year follow-up study. Intens Care Med 2010;36:1327–32.
11. ShoemakerWC, MontgomeryES, KaplanE, ElwynDH. Physiologic patterns in surviving and nonsurviving shock patients. Use of sequential cardiorespiratory variables in defining criteria for therapeutic goals and early warning of death. Arch Surg 1973;106:630–6.
12. BoydO, GroundsRM, BennettED. A randomized clinical trial of the effect of deliberate perioperative increase of oxygen delivery on mortality in high-risk surgical patients. JAMA 1993;270:2699–707.
13. WilsonJ, WoodsI, FawcettJ, et al. Reducing the risk of major elective surgery: randomised controlled trial of preoperative optimisation of oxygen delivery. BMJ 1999;318:1099–103.
14. TuchschmidtJ, FriedJ, AstizM, RackowE. Elevation of cardiac output and oxygen delivery improves outcome in septic shock. Chest 1992;102:216–20.
15. GattinoniL, BrazziL, PelosiP, et al. A trial of goal-oriented hemodynamic therapy in critically ill patients. SvO2 Collaborative Group. N Engl J Med 1995;333:1025–32.
16. McKendryM, McGloinH, SaberiD, et al. Randomised controlled trial assessing the impact of a nurse delivered, flow monitored protocol for optimisation of circulatory status after cardiac surgery. BMJ 2004;329:258.
17. PearseR, DawsonD, FawcettJ, et al. Early goal-directed therapy after major surgery reduces complications and duration of hospital stay. A randomised, controlled trial [ISRCTN38797445]. Crit Care 2005;9:R687–93.
18. DellingerRP, LevyMM, RhodesA, et al. Surviving sepsis campaign: international guidelines for management of severe sepsis and septic shock: 2012. Crit Care Med 2013;41:580–637.
19. RiversE, NguyenB, HavstadS, et al. Early goal-directed therapy in the treatment of severe sepsis and septic shock. N Engl J Med 2001;345:1368–77.
20. JonesAE, ShapiroNI, TrzeciakS, et al. Lactate clearance vs central venous oxygen saturation as goals of early sepsis therapy: a randomized clinical trial. JAMA 2010;303:739–46.
21. PinskyMR. Hemodynamic evaluation and monitoring in the ICU. Chest 2007;132:2020–9.
22. PriceHL, DeutschS, MarshallBE, et al. Hemodynamic and metabolic effects of hemorrhage in man, with particular reference to the splanchnic circulation. Circ Res 1966;18:469–74.
23. Hamilton-DaviesC, MythenMG, SalmonJB, et al. Comparison of commonly used clinical indicators of hypovolaemia with gastrointestinal tonometry. Intens Care Med 1997;23:276–81.
24. Bundgaard-NielsenM, HolteK, SecherNH, KehletH. Monitoring of peri-operative fluid administration by individualized goal-directed therapy. Acta Anaesth Scand 2007;51:331–40.
25. LeDouxD, AstizME, CarpatiCM, RackowEC. Effects of perfusion pressure on tissue perfusion in septic shock. Crit Care Med 2000;28:2729–32.
26. BourgoinA, LeoneM, DelmasA, et al. Increasing mean arterial pressure in patients with septic shock: effects on oxygen variables and renal function. Crit Care Med 2005;33:780–6.
27. BartelsK, ThieleRH, GanTJ. Rational fluid management in today’s ICU practice. Crit Care 2013;17 Suppl 1:S6.
28. MillerRD. Miller’s Anesthesia. Philadelphia, PA: Churchill Livingstone/Elsevier, 2010:1 online resource (2 v. (xxii, 3084, I-89 p.)).
29. CruzDN, RicciZ, RoncoC. Clinical review: RIFLE and AKIN – time for reappraisal. Crit Care 2009;13:211.
30. VincentJL, GerlachH. Fluid resuscitation in severe sepsis and septic shock: an evidence-based review. Crit Care Med 2004;32:S451–4.
31. OsmanD, RidelC, RayP, et al. Cardiac filling pressures are not appropriate to predict hemodynamic response to volume challenge. Crit Care Med 2007;35:64–8.
32. MarikPE, BaramM, VahidB. Does central venous pressure predict fluid responsiveness? A systematic review of the literature and the tale of seven mares. Chest 2008;134:172–8.
33. KumarA, AnelR, BunnellE, et al. Pulmonary artery occlusion pressure and central venous pressure fail to predict ventricular filling volume, cardiac performance, or the response to volume infusion in normal subjects. Crit Care Med 2004;32:691–9.
34. MichardF, TeboulJL. Predicting fluid responsiveness in ICU patients: a critical analysis of the evidence. Chest 2002;121:2000–8.
35. AntonelliM, LevyM, AndrewsPJ, et al. Hemodynamic monitoring in shock and implications for management. International Consensus Conference, Paris, France, 27–28 April 2006. Intens Care Med 2007;33:575–90.
36. WheelerAP, BernardGR, ThompsonBT, et al. Pulmonary-artery versus central venous catheter to guide treatment of acute lung injury. N Engl J Med 2006;354:2213–24.
37. HarveyS, HarrisonDA, SingerM, et al. Assessment of the clinical effectiveness of pulmonary artery catheters in management of patients in intensive care (PAC-Man): a randomised controlled trial. Lancet 2005;366:472–7.
38. SandhamJD, HullRD, BrantRF, et al. A randomized, controlled trial of the use of pulmonary-artery catheters in high-risk surgical patients. N Engl J Med 2003;348:5–14.
39. BowdleTA. Complications of invasive monitoring. Anesthesiol Clin North Am 2002;20:571–88.
40. HamiltonMA, CecconiM, RhodesA. A systematic review and meta-analysis on the use of preemptive hemodynamic intervention to improve postoperative outcomes in moderate and high-risk surgical patients. Anesth Analg 2011;112:1392–402.
41. ZimmermannA, KufnerC, HofbauerS, et al. The accuracy of the Vigileo/FloTrac continuous cardiac output monitor. J Cardiothoracic Vasc Anesth 2008;22:388–93.
42. GoepfertMS, ReuterDA, AkyolD, et al. Goal-directed fluid management reduces vasopressor and catecholamine use in cardiac surgery patients. Intens Care Med 2007;33:96–103.
43. KapoorPM, KakaniM, ChowdhuryU, et al. Early goal-directed therapy in moderate to high-risk cardiac surgery patients. Ann Cardiac Anaesth 2008;11:27–34.
44. SingerM. Esophageal Doppler monitoring of aortic blood flow: beat-by-beat cardiac output monitoring. Internat Anesth Clin 1993;31:99–125.
45. DarkPM, SingerM. The validity of trans-esophageal Doppler ultrasonography as a measure of cardiac output in critically ill adults. Intens Care Med 2004;30:2060–6.
46. RocheAM, MillerTE, GanTJ. Goal-directed fluid management with trans-oesophageal Doppler. Best Pract Res Clin Anaesth 2009;23:327–34.
47. FunkDJ, MorettiEW, GanTJ. Minimally invasive cardiac output monitoring in the perioperative setting. Anesth Analg 2009;108:887–97.
48. SquaraP, DenjeanD, EstagnasieP, et al. Noninvasive cardiac output monitoring (NICOM): a clinical validation. Intens Care Med 2007;33:1191–4.
49. MarqueS, CariouA, ChicheJD, SquaraP. Comparison between Flotrac-Vigileo and Bioreactance, a totally noninvasive method for cardiac output monitoring. Crit Care 2009;13:R73.
50. RavalNY, SquaraP, ClemanM, et al. Multicenter evaluation of noninvasive cardiac output measurement by bioreactance technique. J Clin Monit Comput 2008;22:113–19.
51. BenomarB, OuattaraA, EstagnasieP, BrussetA, SquaraP. Fluid responsiveness predicted by noninvasive bioreactance-based passive leg raise test. Intens Care Med 2010;36:1875–81.
52. MarikPE, LevitovA, YoungA, AndrewsL. The use of bioreactance and carotid Doppler to determine volume responsiveness and blood flow redistribution following passive leg raising in hemodynamically unstable patients. Chest 2013;143:364–70.
53. WaldronNH, MillerTE, NardielloJ, ManchesterAK, GanTJ. NICOM versus EDM guided goal directed fluid therapy in the perioperative period. Anesthesiology 2011.
54. BogertLW, WesselingKH, SchraaO, et al. Pulse contour cardiac output derived from non-invasive arterial pressure in cardiovascular disease. Anaesthesia 2010;65:1119–25.
55. ChenG, MengL, AlexanderB, et al. Comparison of noninvasive cardiac output measurements using the Nexfin monitoring device and the esophageal Doppler. J Clin Anesth 2012;24:275–83.
56. Bubenek-TurconiSI, CraciunM, MicleaI, PerelA. Noninvasive continuous cardiac output by the nexfin before and after preload-modifying maneuvers: a comparison with intermittent thermodilution cardiac output. Anesth Analg 2013;117:366–72.
57. FischerMO, CoucoravasJ, TruongJ, et al. Assessment of changes in cardiac index and fluid responsiveness: a comparison of Nexfin and transpulmonary thermodilution. Acta Anaesth Scand 2013;57:704–12.
58. MonnetX, PicardF, LidzborskiE, et al. The estimation of cardiac output by the Nexfin device is of poor reliability for tracking the effects of a fluid challenge. Crit Care 2012;16:R212.
59. Romero-BermejoFJ, Ruiz-BailenM, Guerrero-De-MierM, Lopez-AlvaroJ. Echocardiographic hemodynamic monitoring in the critically ill patient. Curr Cardiol Rev 2011;7:146–56.
60. BruchC, ComberM, SchmermundA, et al. Diagnostic usefulness and impact on management of transesophageal echocardiography in surgical intensive care units. Am J Cardiol 2003;91:510–13.
61. TeboulJL, MonnetX. Prediction of volume responsiveness in critically ill patients with spontaneous breathing activity. Curr Opin Crit Care 2008;14:334–9.
62. HoferCK, CannessonM. Monitoring fluid responsiveness. Acta Anaesth Taiwan 2011;49:59–65.
63. GoepfertMS, RichterHP, EulenburgCZ, et al. Individually optimized hemodynamic therapy reduces complications and length of stay in the intensive care unit: a prospective, randomized controlled trial. Anesthesiology 2013;119(4):824–36.
64. RamsinghDS, SanghviC, GamboaJ, CannessonM, ApplegateRL, 2nd. Outcome impact of goal directed fluid therapy during high risk abdominal surgery in low to moderate risk patients: a randomized controlled trial. J Clin Monit Comput 2013;27:249–57.
65. ScheerenTW, WiesenackC, GerlachH, MarxG. Goal-directed intraoperative fluid therapy guided by stroke volume and its variation in high-risk surgical patients: a prospective randomized multicentre study. J Clin Monit Comput 2013;27:225–33.
66. AulerJO, Jr., GalasF, HajjarL, et al. Online monitoring of pulse pressure variation to guide fluid therapy after cardiac surgery. Anesth Analg 2008;106:1201–6.
67. LopesMR, OliveiraMA, PereiraVO, LemosIP, AulerJO, Jr., MichardF. Goal-directed fluid management based on pulse pressure variation monitoring during high-risk surgery: a pilot randomized controlled trial. Crit Care 2007;11:R100.
68. CannessonM, BesnardC, DurandPG, BoheJ, JacquesD. Relation between respiratory variations in pulse oximetry plethysmographic waveform amplitude and arterial pulse pressure in ventilated patients. Crit Care 2005;9:R562–8.
69. SandroniC, CavallaroF, MaranoC, et al. Accuracy of plethysmographic indices as predictors of fluid responsiveness in mechanically ventilated adults: a systematic review and meta-analysis. Intens Care Med 2012;38:1429–37.
70. HoodJA, WilsonRJ. Pleth variability index to predict fluid responsiveness in colorectal surgery. Anesth Analg 2011;113:1058–63.
71. ForgetP, LoisF, de KockM. Goal-directed fluid management based on the pulse oximeter-derived pleth variability index reduces lactate levels and improves fluid management. Anesth Analg 2010;111:910–14.
72. MonnetX, RienzoM, OsmanD, et al. Passive leg raising predicts fluid responsiveness in the critically ill. Crit Care Med 2006;34:1402–7.
73. PreauS, SaulnierF, DewavrinF, DurocherA, ChagnonJL. Passive leg raising is predictive of fluid responsiveness in spontaneously breathing patients with severe sepsis or acute pancreatitis. Crit Care Med 2010;38:819–25.
74. da Silva RamosFJ, AzevedoLC. Hemodynamic and perfusion end points for volemic resuscitation in sepsis. Shock 2010;34 Suppl 1:34–9.
75. NguyenHB, KuanWS, BatechM, et al. Outcome effectiveness of the severe sepsis resuscitation bundle with addition of lactate clearance as a bundle item: a multi-national evaluation. Crit Care 2011;15:R229.
76. NguyenHB, RiversEP, KnoblichBP, et al. Early lactate clearance is associated with improved outcome in severe sepsis and septic shock. Crit Care Med 2004;32:1637–42.
77. RutherfordEJ, MorrisJA, Jr., ReedGW, HallKS. Base deficit stratifies mortality and determines therapy. J Trauma 1992;33:417–23.
78. HolleyA, LukinW, ParatzJ, et al. Review article: Part two: Goal-directed resuscitation – which goals? Perfusion targets. Emerg Med Aust 2012;24:127–35.
79. LongneckerDE. Anesthesiology. New York: McGraw-Hill Medical, 2008.
80. PolonenP, RuokonenE, HippelainenM, PoyhonenM, TakalaJ. A prospective, randomized study of goal-oriented hemodynamic therapy in cardiac surgical patients. Anesth Analg 2000;90:1052–9.
81. DueckMH, KlimekM, AppenrodtS, WeigandC, BoernerU. Trends but not individual values of central venous oxygen saturation agree with mixed venous oxygen saturation during varying hemodynamic conditions. Anesthesiology 2005;103:249–57.
82. ReinhartK, KuhnHJ, HartogC, BredleDL. Continuous central venous and pulmonary artery oxygen saturation monitoring in the critically ill. Intens Care Med 2004;30:1572–8.
83. DonatiA, LoggiS, PreiserJC, et al. Goal-directed intraoperative therapy reduces morbidity and length of hospital stay in high-risk surgical patients. Chest 2007;132:1817–24.
84. DavisonDL, ChawlaLS, SelassieL, et al. Femoral-based central venous oxygen saturation is not a reliable substitute for subclavian/internal jugular-based central venous oxygen saturation in patients who are critically ill. Chest 2010;138:76–83.
85. MarikPE. Sublingual capnography: a clinical validation study. Chest 2001;120:923–7.
86. MarikPE. Regional carbon dioxide monitoring to assess the adequacy of tissue perfusion. Curr Opin Crit Care 2005;11:245–51.
87. PalizasF, DubinA, RegueiraT, et al. Gastric tonometry versus cardiac index as resuscitation goals in septic shock: a multicenter, randomized, controlled trial. Crit Care 2009;13:R44.
88. RinehartJ, LiuN, AlexanderB, CannessonM. Review article: closed-loop systems in anesthesia: is there a potential for closed-loop fluid management and hemodynamic optimization?Anesth Analg 2012;114:130–43.
89. SrinivasaS, KahokehrA, SoopM, TaylorM, HillAG. Goal-directed fluid therapy-a survey of anaesthetists in the UK, USA, Australia and New Zealand. BMC Anesth 2013;13:5.